MIC-G integrative acceleration transmitter
General
KH-HZD-F Explosion-proof integrative vibration transmitter, integrating the traditional vibration sensor and the accuracy measuring circuit together, not only achieve “sensor + transmitter” mode vibration measurement system function, but also achieve economic but high accuracy vibration measure system. The transmitter can connect directly with PLC, DCS or other systems. Mounted on the bearing cover of rotating machines, the transmitter is an ideal choice for steam turbine, compressors, motors, blower, fans, water pump etc to measure vibration speed or vibration amplitude. Because its output signals are caused by moving coils cutting magnetic force line, so its power supply can be 24VDC, easy installation and maintenance. The transmitter can be used widely in heating and power plant, cement plant, machine plant, blower plant, paper made plant, coal mine machine etc.
Mounting method: vertical or horizontal mounted on the measured vibrating point
Specification
Sensitivity: 20mv/mm/s±5% 30mv/mm/s±5% 50mv/mm/s±5%
Frequency Response: 5-1000Hz
Measuring Range0-10mm/s 0-20mm/s 0-30.0mm/s 0-40.0mm/s 0-50.0mm/s
Signal Output: standard current 4-20mA (default when order) RS485
Output Impedance: ≤500
Power supply: DC24V
Max acceleration: 10g
Measurement Direction: vertical or horizontal
Mounting method: vertical or horizontal mounted on the measured vibrating point
Mounting thread: M10X1.5,
Ambient Temperature: -30℃ to 50℃,
Relative humidity: ≤90%
Size: φ45×90mm, about 350g
Weight: About 1.25kg

Installation
1) RS485 Leading Cable: Blue-A ,Gree-B, Red-DC24,Black-GND
2) Baud rate:9600 Address: 1
3) Calibration: Please connect the ammeter positive terminate “+” to yellow wire, the negative terminate“-“to black wire; Power supply DC24V “+” to red wire, DC24V “-“to black wire.
When without signal input, the ammeter displays 4.00mA. If not display 4.00mA, please adjust the potentiometer (rectangular) to make the current as 4.00mA.
Please adjust the range of the vibration calibration instrument to the required one. So the ammeter will display 20.00mA. If not 20.00mA, please adjust the potentiometer (rectangular) to make the current as 20.00mA.
4) Mounting :( Picture1). The transmitter can be mounted vertically or horizontal in the measured point. Please fix the screw bolt M20X1.5 in measured object. Then screw on the transmitter.
5) When installed part of the transmitter is scoured by steam, please make some protection on transmitter in order to reduce the working ambient temperature and humidity of transmitter. In normal condition, no need any protection.
6)Protection on transmitter can be made according to the field demand. Reference as follows:


Note:
1.1Strong shock and knock should be avoided on transmitter
The transmitter should be packed in the box during the transport and storage.