Intelligent Thermocouple transmitter

Short Description:

The intelligent temperature transmitter can change the model of the sensor and the corresponding temperature range. It can be used by downloading free software.

KH213 series temperature transmitter module iswith 24V power supply, two-wire system of integrated transmitter. Products adopts imported integrated circuits, the thermal resistance or thermocouple signal amplification and conversion into 4-20mA or 0-10mA output current, or 0 ~ 5V output voltage. One armored transmitter can directly measure the gas or liquid temperature is particularly suitable for low temperature range measurement, to overcome the condensation of water on the impact of temperature measurement.

Thermal resistance measurement range: PT100:-200~650℃;CU50:-50~150℃
Thermocouple measurement range: K type:300~1200℃; E type:200~800℃;S type:600~1600℃
Output siginal: 4-20mA,0-10mA,0-10V,0-5V
Measurement accuracy: Thermocouple measurement:0.2~0.3% Thermocouple:1~2%
Temperature drift: 0.025%/℃
Power supply: +12VDC or +24VDC±10% Work environment: 0~70℃ Storage Conditions: -40~+85℃

 


  • :
  • Product Detail

    Product Tags

    Dimensions and installation

    KH213温度智能变送器尺寸与安装图

    Parameter

    Output Signal: 4-20mA
    Max Load:max. (V power supply-7.5V)/0.022A (current output)
    Measurement:tempt-lineatiry,resistance-linearity, voltage-linearity
    Circuit limit: <=22Ma
    Response time: <=1second
    Saturation current: Low side 3.9mA, high side 20.5Ma
    Alarm current: sensor damger or sensor turnoff output is 3.9mA or 22mA(except TC)
    Accuracy: 0.1%FS
    Measuring accuracy is related to m
    Power supply: U=12V to 40V
    Working temperature: -40 to 85℃
    Storage temperature: -40 to 100℃
    Condenstaion: Allowable
    Protection: IP00; IP66 (mounted)
    Earthquake resistance:4g/2 to 150HZ
    Voltage effection: can ignore
    Mounted angle: no limit

    Transfer various kinds of input signal into 4-20mA output
    Input: RTD, Thermocouple
    Configuration by PC
    2 kinds of resistance thermometer input (RTD)
    8 kinds of thermocouple (TC)
    Built-in cold junction compensation
    Input:

    Model Type Measuring Range Min Range
    RTD Pt100 -200 to 600℃ 10K
    Cu50 -50 to150℃ 10K
    TC B 400 to 1820℃ 500K
    E -100 to 1000℃ 50K
    J -100 to 1200℃ 50K
    K -180 to 1372℃ 50K
    N -180 to 1300℃ 50K
    R -50 to 1760℃ 500K
    S -50 to 1760℃ 500K
    T -200 to 400℃ 50K

    Wire Connection

    KH213温度智能变送器j接线图

    Device real-time monitoring query

    The equipment uses RS485 communication connection acquisition card to achieve real-time recording, monitoring and query

    pro01

    Wireless transmission of data

    Cloud acquisition software, only NEED 4G wireless module communication, no wiring, easy to install! Mobile phone computer remote view data or graph, at the same time with SMS alarm function.

    pro3

    Company profile

    Xiamen mitcheil automation co., Ltd. is a professional manufacturer of industrial instruments, advanced technology and CE, ROHS, ISO certification can ensure the quality. Our own production plant can ensure price advantage.

    Temperature

    At present, the company's trade scale is expanding day by day, customers all over the world, with good reputation has been the trust of customers at home and abroad, our enthusiasm hope: you and I hand in hand, create a better future!

    Temperature

    Packaging and Transportation

    Packing: Put PC into bubble bag first, and then into carton

    Accessories: Manual, U disk

    Air freight: DHL, TNT and other express


  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • temperature sensor waterproof room oil pt 100 thermocouple k-type exhaust small temperature sensor

      temperature sensor waterproof room oil pt 100 t...

      K Type thermocouple with metal sheath or lead cable is widely used in aviation, nuclear, petroleum, chemical, metallurgical, mechanical,electrical and other industrial sectors and scientific fields; K type is usually used with indicator, recorder, controller, and computer and other devices. K type can direct measure a variety of liquid, steam& gas and solid surface temperature from 0℃ to 1300℃. Especially suitable to be installed in special miniaturized tempe...

    • Thermocouple wire

      Thermocouple wire

      Specification Product model Thermocouple temperature line Wire core material Nickel-chromium/Nickel-silicon (TYPE K) Copper/Copper-nickel (Type T) Nickel Silicon (TYPE E) Iron/Copper Nickel (Type J) Temperature measurement -200℃-260℃(Four fluorine) -200℃-500℃( glass fiber) Custom items: 1.Insulating material:Teflon /PFA/GG(glass fiber), high temperature glass fiber, silica 2.Thermocouple selection:k、T、J 3.diameter:...

    • MIC300G Paperless Recorder 16Channels

      MIC300G Paperless Recorder 16Channels

      Specification Analog Input Specification Accuracy ±(0.2%FS+1)digit Power supply 100-240VAC  or  24VAC Input Signal T.C: K, S, E, J, T, B, N, R, WRe526, WRe325 RTD: PT100, CU50, CU100 Linear voltage: 0-5V, 1-5V Linear current: 0-10mA, 4-20mA Frequency input: 0-5KHZ, one channel Others: 0-20mV,0-60mV, 0-100mV, 0-500mV Output Module 16 channels relay alarm output (Max) 4-20mA Retransmission output RS485 communication port RS...

    • thermocouple types – pressure ring type

      thermocouple types – pressure ring type

      Specification Product model thermocouple types - pressure ring type Type  Type K thermocouple/ PT100 Accuracy grade Class I, Class II Lead material Two/three silver plated FEP shielding wire Probe size Support for custom Wire length Support for custom Temperature range K (- 50 ~ 1300 ℃) PT100: -200 to 500℃ for Class A, -200 to 600℃ for Class B Cu50 ( -50 ~ 150℃ ) , Cu100 ( -50 ~ 150℃ ) Protection tube material  PVC cable, hi...

    • Curve temperature controller-KH104 Manual

      Curve temperature controller-KH104 Manual

      Specification ● Accuracy: 0.5% ● Respond time: ≤0.5s when the filtering parameter FiL=0 ● Output Specification: Relay alarm outputs: 220VAC/3A, 220VAC/0.8A SSR voltage driving output: 12VDC/30Ma Linear current retransmission output: 4-20Ma default or 0-10Ma or customized Communication output: RS485, RS232 serial interface ● Alarm Function High limit, higher limit, low limit, lower limit, up to3 alarm output. ● Power Supply: 85-240VAC,-15%,...

    • MIC800G 8Channels Extensible Data Logger

      MIC800G 8Channels Extensible Data Logger

      Specification Analog Input Specification Input Signal Thermocouple: 10 types (K,S,B,E,J,N,R,T,WRe526,WRe325) RTD-Resistance bulbs: 3 types(Pt100, CU50,CU100) Linear DC Voltage: (0-5VDC, 1-5VDC,0-10VDC) DC Current: (4-20mA, 0-10 mA) mV:0-20mV,0-60mV, 0-100mV, 0-500mV Accuracy 0.2 grade when RTD, linear voltage, linear current and T.C input 0.2%FS±2.0℃ when T.C input with cold junction compensation by internal part of recorder. Sam...